Skip to main content Skip to footer

Coating mini-tablets in a tablet coater: How optimised coater drums open up new process windows

Contact us for a non-binding consultation

Mini-tablets are becoming increasingly important in pharmaceutical development and production. These solid dosage forms, measuring only 1 to 3 mm in size, enable flexible dosing concepts, improve patient convenience, and support controlled drug release. However, their small size presents significant challenges for tablet coating. This article explains the process engineering challenges involved in coating mini-tablets, emphasizing the importance of coater drum design and process control in achieving consistent results.

 

Why mini-tablets are gaining importance in tablet manufacturing

Mini-tablets are among the most innovative solid dosage forms in the modern pharmaceutical industry. With diameters typically ranging from 1 to 3 mm, they offer several advantages over conventional tablets. 

Particularly in pediatrics, geriatrics, and for patients with swallowing difficulties, mini-tablets enable easier administration. In addition, they allow flexible dosing concepts and the combination of different drug release profiles within a single dosage form.

With the growing use of this dosage form, the importance of efficient processes for mini-tablet coating is also increasing. Coating not only serves to protect the product but often fulfills critical pharmaceutical functions.

Typical objectives of tablet coating include:

  • Protection of the active ingredient against moisture, oxygen, or light
  • Masking of unpleasant tastes
  • Improvement of mechanical stability
  • Control of active ingredient release
  • Enteric or sustained-release delivery systems

The requirements for coating quality are identical to, or even higher than, those for conventional tablets.

What is the technical challenge of coating mini-tablets?

A tablet coater is based on the principle of a rotating coating drum. The products are continuously moved while a spray system applies the coating suspension. At the same time, an airflow ensures controlled drying.

For standard tablets, this process works reliably. However, mini-tablets present unique challenges.

Small product size increases the risk of product loss

The greatest process engineering challenge arises from the relationship between product size and the perforation diameter of the coating drum.

While conventional tablets typically measure several millimeters to centimeters, mini-tablets range from only 1 to 3 mm in diameter. Conventional perforation patterns are often designed for larger product forms.

If the openings are too large, risks include:

  • Loss of individual particles through the perforations
  • Uncontrolled product movement
  • Impairment of airflow characteristics
  • Fluctuations in the coating process
  • Reduced coating quality in terms of film thickness and uniformity

As a result, the design requirements for the coater drum increase significantly.

Why fluid bed systems are often used instead

Due to these challenges, mini-tablet coating is traditionally carried out in many production environments using a fluid bed processor.

In this process, the particles are fluidized by an airflow and subsequently sprayed with coating solutions. The technology is particularly suitable for small particles and is an established method for coating pellets and mini-tablets.

However, the use of different equipment types also introduces disadvantages:

  • Additional capital investment
  • Higher training and validation efforts
  • Increased production complexity
  • Additional space requirements
  • Greater demands on cleaning and maintenance

Against this background, there is growing interest in solutions that enable the coating of all tablet sizes within a single system.

Which role does coater drum perforation play?

The perforation of a coater drum has a significant impact on the process stability of a coating operation. 

Its functions include:

  • Guiding the process airflow
  • Supporting heat and mass transfer
  • Ensuring reliable product handling
  • Preventing product losses

For very small products, even a slight change in perforation diameter can significantly influence process performance.

A reduced perforation size can help to:

  • Safely retain mini-tablets within the drum
  • Increase product yield
  • Control the process airflow more precisely
  • Achieve stable coating results

As a result, the application range of a laboratory coater or production coater can be extended to accommodate smaller product sizes.

Flexible coating processes for different tablet sizes

A key trend in pharmaceutical manufacturing is the flexible use of equipment for different product formats.

Manufacturers are increasingly faced with the challenge of processing smaller batch sizes, more frequent product changeovers, and different dosage forms in a cost-effective manner. Equipment concepts capable of handling standard tablets, mini-tablets, and pellets within the same system support these requirements

Through optimized drum geometries and finer perforation patterns, a modern tablet coater can now cover a much broader product portfolio than was possible just a few years ago. 

This enables:

  • Higher equipment utilization
  • Lower investment costs
  • Simplified qualification and validation
  • Reduced equipment complexity
  • More flexible development and production processes

Particularly in research and development applications, users benefit from a laboratory coater that can process different product sizes without requiring a change of equipment.

Learn more about the LÖDIGE Coater LC

Frequently asked questions about mini-tablet coating

Can mini-tablets be coated in a tablet coater? 

Yes. The prerequisites are a process setup adapted to the small product size, as well as a suitable design of the coater drum and its perforation. 

Why is drum perforation so important? The perforation affects both airflow management and product retention within the drum. If the openings are too large, product losses or process instabilities may occur. 

What are the advantages of coating in a tablet coater compared to a fluid bed system? Depending on the application, using a single system for different tablet sizes can simplify production processes and reduce investments in additional equipment. Coating in a tablet coater is also faster than in a fluid bed processor.

For which products are finely perforated coater drums of interest?

Typical application areas include:

  • Mini-tablets
  • Pellets
  • Multiparticulate dosage forms
  • Development batches
  • Specialized modified-release formulations

Conclusion

Mini-tablets are becoming an increasingly important dosage form in the pharmaceutical industry. However, their small size places high demands on mini-tablet coating, particularly with regard to the design of the coater drum, airflow management, and process control.

Request individual advice now

WE ARE CERTIFIED & APPROVED

Our commitment to quality is officially confirmed by recognized testing bodies. Learn here more about our industry-specific approvals and certificates.

Let's get talking

Do you have any questions, suggestions or feedback? Let us know your request via the contact form and we will get back to you as soon as possible.

Find contact person

By sending the contact enquiry, you agree to our privacy policy.